InvasionInversionResult¶
petrophys.interpretation.electrical.invasion.InvasionInversionResult
- class InvasionInversionResult(
- rt,
- rxo,
- di,
- misfit,
- at_limit,
- deep_flushed_share=<factory>,
- rt_low=<factory>,
- rt_high=<factory>,
- di_low=<factory>,
- di_high=<factory>,
- readings=(),
- notes=<factory>,
Per-sample step-profile solution.
Attributes
Root-mean-square relative misfit of the readings.
1 where the best diameter lies on the edge of the searched range.
its share from the flushed zone.
Range of Rt and di over every solution that fits the readings within
noise: the step model is non-unique (conductive invasion read by induction tools especially), and this range is its uncertainty.- Parameters:
its share from the flushed zone. Above about 0.5 Rt rests on a small part of the signal and is poorly determined.
- Type:
J of the deepest reading at the solved diameter