02 - QA/QC and Standardization

Open in Colab

Part A - Foundations - Petrophys Curriculum

Raw logs are never quite ready for interpretation. Curves carry inconsistent names, mixed units, physically impossible spikes, and intervals where the borehole itself was too poor for the tool to read correctly. Data conditioning - QA/QC - fixes these before any physics runs. Garbage in, garbage out is nowhere more true than in petrophysics.

This lesson works through the petrophys.preprocessing toolkit:

  1. Curve standardization - map messy mnemonics to standard names, convert units.

  2. Value-range QC - null out physically impossible values.

  3. Bad-hole / washout detection - flag intervals where the borehole is unreliable.

  4. Multi-well normalization - put a curve on a common scale across a field.

Learning goals

  • Standardize mnemonics and units with CurveStandardizer / standardize_curves and the ALIAS_MAP.

  • Recognize a wrong unit label on core saturation and declare the right one with standardize_core_saturation.

  • Apply value-range QC with apply_value_range_qc and read its value_range_qc_note.

  • Detect washout / bad hole from caliper (CALI) vs bit size (BS) with detect_washout / WashoutDetection, and set the bad-hole thresholds of pp.interpret.

  • Normalize a curve across wells with NormalizationModule, and understand why multi-well normalization is needed.

  • See before/after for each step and be able to justify every QC decision.

Why this matters

  • Standardization lets one workflow run over a whole field: if every well calls its deep resistivity something different (RT, ILD, LLD, …), no batch process can find it. Mapping them all to RDEP fixes that.

  • Value-range QC removes non-physical readings (a neutron porosity of 3.0, a negative gamma ray) that would otherwise poison averages and crossplots.

  • Bad-hole detection protects density-based answers. Where the hole washes out, the density pad loses contact and RHOB reads too low - which would fake high porosity. The caliper-minus-bit-size, \(\mathrm{CALI}-\mathrm{BS}\), is the classic washout indicator.

  • Normalization removes well-to-well bias (tool calibration, mud, borehole) so that, say, a GR cutoff for “clean sand” means the same thing in every well.

Prerequisites

This lesson assumes lessons 00 and 01 - you should be comfortable loading a Well, reading Curve statistics, and knowing that GeoLink is in metres and COSTA in feet. pp.read keeps the curve names and units exactly as written in the file - which is what we want to inspect and standardize.

import pandas as pd
import petrophys as pp

1. Curve standardization

Different vendors and eras name the same measurement differently. petrophys ships an ALIAS_MAP (standard mnemonic -> list of known aliases) and a CurveStandardizer that uses it to rename curves and convert units. Here are the first ten names that all mean “deep resistivity”:

from petrophys.preprocessing import ALIAS_MAP, CurveStandardizer, standardize_curves

ALIAS_MAP["RDEP"][:10]
['RT', 'ILD', 'RILD', 'LLD', 'AT90', 'AT60', 'HRLT', 'RESD', 'RD', 'RDEEP']

Take the carbonate well HW-3. Its sonic is DT and its true resistivity is RT - both non-standard. A dry-run report shows what would change, without touching the data.

wc = pp.read(pp.sample("HW-3"))
CurveStandardizer().report(wc)
{'total_curves': 8,
 'recognized': [{'original': 'GR', 'standard': 'GR'},
  {'original': 'RHOB', 'standard': 'RHOB'},
  {'original': 'NPHI', 'standard': 'NPHI'},
  {'original': 'DT', 'standard': 'DTC'},
  {'original': 'PHIE_CC', 'standard': 'PHIE_CC'},
  {'original': 'RT', 'standard': 'RDEP'},
  {'original': 'PERM_CC', 'standard': 'PERM_CC'}],
 'unrecognized': ['SW_INPUT'],
 'duplicates': [],
 'unit_conversions': [{'curve': 'GR', 'from_unit': 'gAPI', 'to_unit': 'API'},
  {'curve': 'NPHI', 'from_unit': 'ft3/ft3', 'to_unit': 'v/v'}]}

The report tells us exactly four things will happen: DT -> DTC, RT -> RDEP, the gamma-ray unit label is normalized (gAPI -> API), and the neutron unit label ft3/ft3 becomes v/v (the same fraction, so the values do not change). API and gAPI denote the same gamma-ray scale, so there too only the label changes. SW_INPUT is unrecognized (a project-specific name), so standardization does not rename it or convert its unit - a safe default. PHIE_CC and PERM_CC are recognized under their own names.

Apply it. standardize_curves returns the standardized well (it mutates the well in place), so we standardize a fresh copy and compare it with the curves as read.

wc.curves, standardize_curves(pp.read(pp.sample("HW-3"))).curves
(['GR', 'RHOB', 'NPHI', 'DT', 'PHIE_CC', 'RT', 'SW_INPUT', 'PERM_CC'],
 ['GR', 'RHOB', 'NPHI', 'DTC', 'PHIE_CC', 'RDEP', 'SW_INPUT', 'PERM_CC'])

Core saturation: percent versus fraction

A unit label can be wrong. The bundled 30/6-5 SWC header says frac, but its values run from 13.7 to 84.6 - percentages. standardize_core_saturation infers the conversion, warns, and records the evidence on the returned curve; the curve on the well is left unchanged. Inference is a heuristic: mixed, sparse or entirely sub-1-percent observations cannot always be classified numerically.

from petrophys.preprocessing import standardize_core_saturation

swc = pp.read(pp.sample("30_6-5"))["SWC"]
standardize_core_saturation(swc).metadata.custom["core_saturation_normalization"]
[temporary directory]\ipykernel_8424\2181876070.py:4: UserWarning: SWC: inferred percent core saturation despite unit 'frac'; divided by 100 to v/v. Verify source units.
  standardize_core_saturation(swc).metadata.custom["core_saturation_normalization"]
{'original_unit': 'frac',
 'source_unit': None,
 'target_unit': 'v/v',
 'factor': 0.01,
 'reason': 'inferred_percent',
 'masked_count': 0,
 'warnings': ["SWC: inferred percent core saturation despite unit 'frac'; divided by 100 to v/v. Verify source units."]}

Once the lab report confirms the unit, declare it with source_unit instead of relying on inference; the result is the same 0.137-0.846 v/v without a warning. Use an explicit override only after checking the lab/source units, and apply it to an original, unnormalized curve: a curve already converted, declared source_unit="v/v", is left as it is, never divided by 100 again. Invalid observations are masked, not clipped into plausible values. A unit correction does not make measured core saturation equivalent to in-situ log saturation.

standardize_core_saturation(swc, source_unit="%").describe()
{'count': 74,
 'null_count': 22102,
 'min': 0.13699999999999998,
 'max': 0.846,
 'mean': 0.48239189189189186,
 'std': 0.15787626163648744,
 'median': 0.47350000000000003,
 'p25': 0.3655,
 'p75': 0.60125}

This unit note repeats every time 30/6-5 is plotted or interpreted. Having read it, the next cell hides only this message for the rest of the lesson; other warnings stay visible.

import warnings

warnings.filterwarnings("ignore", message=r"(SWC|SOC): inferred percent core saturation")

2. Value-range QC

apply_value_range_qc(well) walks each curve, looks up its configured plausible range in VALUE_RANGE_RULES, and either nulls (sets to NaN) or clips out-of-range values. It returns a per-curve report, shown below for the curves it changed; value_range_qc_note renders that report as a readable sentence.

We use the GeoLink well 30_6-5 because its raw curves contain real out-of-range values (a handful of negative GR samples, out-of-bounds NPHI and PEF, and deep-resistivity readings pegged at the 2000 ohm.m top of the tool range).

from petrophys.preprocessing import apply_value_range_qc, value_range_qc_note

w = pp.read(pp.sample("30_6-5"))
report = apply_value_range_qc(w)   # changes w: out-of-range values -> NaN or clipped
pd.DataFrame(report).query("changed > 0")
curve canonical_curve low high action changed below above
1 NPHI NPHI -0.15 0.6 nan 299 0 299
3 PEF PEF 0.00 15.0 nan 35 0 35
4 GR GR 0.00 400.0 nan 3 3 0
7 RDEP RDEP 0.01 2000.0 nan 9 0 9
print(value_range_qc_note(report))
VALUE RANGE QC: finite values outside configured ranges were set to NaN; SW/SWA and SXO/SWXO/SWXOA were clipped to 0-1. Changed: NPHI set NaN=299 (<-0.15:0, >0.6:299); PEF set NaN=35 (<0.0:0, >15.0:35); GR set NaN=3 (<0.0:3, >400.0:0); RDEP set NaN=9 (<0.01:0, >2000.0:9).

Reading the result: the 3 negative gamma-ray samples (physically impossible - GR cannot be below 0) were nulled, and 299 neutron porosities above 0.6 and 35 PEF values above 15 b/e were removed. The 9 RDEP values above 2000 ohm.m are a different case. All 9 sit at 177-242 m, at the top of the logged hole (36-in and 26-in sections), where RDEP is pegged at about 2000 ohm.m - the top of the tool’s range - rather than measuring the rock. The 2000 ohm.m bound is a configured plausibility/tool screen, not a law of physics: it removes the 9 samples a hair above it but keeps nine equally saturated readings at 1999.87-2000.0 ohm.m, and evaporites can legitimately read higher (the Zechstein halite section of 16_7-1 reads beyond the tool’s range). So it is a reviewable screening choice, not a hard physical edit. That mix is exactly why value-range QC uses a curve-specific rule table rather than a blanket filter: some rules encode physics, others encode plausibility.

3. Bad-hole / washout detection

When the borehole caves or washes out, pad-contact tools (especially density) read unreliably. The primary indicator is the caliper exceeding the bit that drilled the hole:

\[\text{washout where } \quad (\mathrm{CALI} - \mathrm{BS}) > \text{threshold} \quad (\text{default } 1.5\ \text{in})\]

An independent check is the density correction \(|\mathrm{DRHO}|\) exceeding a threshold. The combined bad-hole flag is the union of the washout and large-hole flags; the low-density and PEF-exclusion screens are computed separately and reported alongside it for QC reference.

30_6-5 carries both CALI (caliper) and BS (bit size), so it is the right well for this demo. detect_washout(well) uses the BS curve when the header sets no bit size; its statistics give the count, percentage and thickness (m) of each flag over the logged interval.

from petrophys.preprocessing import detect_washout

w = pp.read(pp.sample("30_6-5"))
washout = detect_washout(w)
washout.statistics
{'washout_count': 7841,
 'washout_percent': 35.358044733044736,
 'washout_thickness': 1194.9695649999992,
 'large_hole_count': 5108,
 'large_hole_percent': 23.033910533910536,
 'large_hole_thickness': 778.45928,
 'low_density_count': 11046,
 'low_density_percent': 49.81060606060606,
 'low_density_thickness': 1683.410165,
 'pef_exclusion_count': 134,
 'pef_exclusion_percent': 0.6042568542568543,
 'pef_exclusion_thickness': 20.421395000000302,
 'bad_hole_count': 12631,
 'bad_hole_percent': 56.95797258297258,
 'bad_hole_thickness': 1924.9656149999992}
len(washout.washout_intervals), washout.washout_intervals[:3]
(736, [(901.27203, 949.58289), (955.06927, 955.52649), (955.8313, 960.86047)])

Washout covers 35.4% of the log (1195 m) in 736 separate intervals, and the combined bad-hole flag 57.0% (1925 m), because it also takes every sample of the 26-in and 36-in hole sections (large hole: bit size above 17.5 in).

Attaching and displaying the flags

For downstream use you want the flags as curves on the well, so later steps can mask bad intervals out. WashoutDetection().add_flags_to_well(well) adds WASHOUT_FLAG, BAD_HOLE_FLAG and PEF_EXCL_FLAG, and the log viewer then shades the bad-hole depths in pink across the tracks with a BADHOLE legend entry. The plot shows the evidence: CALI against the dashed BS (the cause) in the gamma-ray track, and RHOB, NPHI and DRHO (the tools you stop trusting) in the density-neutron track. The window, 1950-2150 m, lies in the 12.25-in hole section below the bit change at ~1815 m and holds the washout at about 2020-2100 m, where the caliper runs past the 16-in edge of its scale. NPHI in the shales reads above the 0.45 edge of its scale in places and is clipped there.

from petrophys.preprocessing import WashoutDetection

WashoutDetection().add_flags_to_well(w)
pp.plot(w, top=1950, bottom=2150, curves=["GR", "CALI", "BS", "RHOB", "NPHI", "DRHO"], figsize=(8, 10))
../../_images/40575b36486f700a81853af3b45bba057bc46d56fdcb0717609c7b620c5bd3ac.png

The bad-hole thresholds as interpretation settings

The three tests above - \(\mathrm{CALI}-\mathrm{BS} > 1.5\) in, \(|\mathrm{DRHO}| > 0.15\) g/cm3, and \(\mathrm{BS} > 17.5\) in for large hole - are also the defaults of the bad_hole step of pp.interpret, and its BAD_HOLE curve uses only these three. Each is a setting: bad_hole={"cali": ..., "drho": ..., "large_hole": ...} (in, g/cm3, in) takes the ones you change and keeps the rest. The step’s trace records them, and the bad-hole band of pp.plot follows the BAD_HOLE curve the run writes.

Pick a threshold from the tool and the hole, not from the flagged percentage you would like. The table below gives the 10th percentile and median of CALI - BS for each bit size. In 30/6-5’s 12.25-in hole the caliper reads about 0.75 in over bit size even at its tightest (the 10th percentile). If that offset is the caliper’s calibration - check it against a casing reading - a 1.5-in washout is measured from it: cali 2.25 in. The 8.5-in hole reads in gauge (10th percentile +0.09 in), though, so a whole-well 2.25 in would miss washouts there. In the 26-in and 36-in sections the caliper reads 11-12 in below bit size: it cannot open that wide (its maximum reading is 24.1 in), so it says nothing about those holes.

w.to_dataframe().assign(CALI_BS=lambda d: d.CALI - d.BS).groupby("BS").CALI_BS.quantile([0.1, 0.5]).unstack()
0.1 0.5
BS
8.50 0.0860 2.141
12.25 0.7580 1.266
17.50 0.4220 1.250
26.00 -12.4475 -10.656
36.00 -11.9370 -11.922

Two interpretations show the effect: the default and bad_hole={"cali": 2.25}. The first table gives the share of samples BAD_HOLE flags in the 12.25-in section (1815-2805 m) and over the whole well; the second lists the decisions the bad_hole step recorded for the 2.25-in run.

default = pp.interpret(w)
looser = pp.interpret(w, bad_hole={"cali": 2.25})   # 1.5 in beyond the ~0.75 in offset
pd.DataFrame({name: {"12.25-in hole": run.well["BAD_HOLE"].depth_slice(1815, 2805).mean(),
                     "whole well": run.well["BAD_HOLE"].mean()}
              for name, run in [("cali 1.5 in", default), ("cali 2.25 in", looser)]})
cali 1.5 in cali 2.25 in
12.25-in hole 0.407482 0.189501
whole well 0.569580 0.445391
looser.step("bad_hole").decisions
['Bad-hole thresholds set: cali=2.25',
 '9877 bad-hole samples flagged out of 22176']

A LAS header can set each threshold - BADHOLE_CALI, BADHOLE_DRHO, BADHOLE_BS - for the well or for one header zone (BADHOLE_CALI_Z1 with TOP_Z1/BOT_Z1). The next cell sets the zone form with set_parameter, the same as the header line BADHOLE_CALI_Z1.in 2.25 : ..., so only the 12.25-in section changes and the 8.5-in hole keeps the 1.5-in test. A value passed to interpret wins over the header.

In the 12.25-in section the 2.25-in caliper test cuts BAD_HOLE from 41% to 19% of the samples. Applied to the whole well it also lowers the whole-well share from 57% to 45%; limited to the header zone it gives 51%, because the 8.5-in hole keeps its washouts.

w_zone = pp.read(pp.sample("30_6-5"))
w_zone.set_parameter("BADHOLE_CALI_Z1", 2.25)
w_zone.set_parameter("TOP_Z1", 1815.0)
w_zone.set_parameter("BOT_Z1", 2805.0)
zoned = pp.interpret(w_zone)
zoned.well["BAD_HOLE"].depth_slice(1815, 2805).mean(), zoned.well["BAD_HOLE"].mean()
(0.18950123152709358, 0.505726911976912)

4. Multi-well normalization

Even after standardization, a curve’s values can be biased well-to-well - different tool calibration, mud, or borehole conditions shift the readings. Before comparing wells (or applying a single cutoff across a field), we normalize to a common scale.

NormalizationModule().normalize applies a linear rescale using low/high anchor points (by default the P5 and P95 percentiles of each curve, robust so outliers do not distort the fit):

\[\text{norm} = \text{min} + (\text{max}-\text{min})\,\frac{\text{log}-\text{low}}{\text{high}-\text{low}}\]

We use five COSTA wells, read in one call from a list of files. First, look at how their raw GR distributions differ.

costa = pp.read([pp.sample(name) for name in ["HW-3", "HW-4", "HW-5", "HW-6", "HW-7"]])
pd.DataFrame({well.name: well["GR"].describe() for well in costa})
HW-3 HW-4 HW-5 HW-6 HW-7
count 431.000000 361.000000 337.000000 417.000000 371.000000
null_count 0.000000 0.000000 0.000000 0.000000 0.000000
min 8.130000 7.000000 12.390000 6.620000 5.840000
max 27.320000 44.000000 45.980000 42.850000 49.470000
mean 12.321949 15.429363 20.743472 12.785204 13.314474
std 3.865740 7.955285 9.319079 6.582209 8.319732
median 10.820000 12.000000 16.590000 9.860000 9.630000
p25 9.785000 11.000000 15.390000 8.650000 8.290000
p75 13.875000 15.000000 19.990000 14.400000 14.395000

The distributions drift from well to well: the median runs from 9.6 API (HW-7) to 16.6 API (HW-5), and the maximum from 27.3 API (HW-3) to 49.5 API (HW-7). Each COSTA file covers the same reservoir zone, Kharaib-2, so we are comparing like with like, although part of the drift can still be real facies variation (see the pitfalls below). If we applied a single GR cutoff to pick clean carbonate, it would mean different things in different wells. Normalizing each well’s GR onto common reference anchors - mapping each well’s own P5 to 0 and P95 to 100 - removes that bias. Values outside P5-P95 can remain below 0 or above 100; the transform does not clip them.

from petrophys.preprocessing import NormalizationModule

normalized = {well.name: NormalizationModule().normalize(well["GR"], 0, 100) for well in costa}
pp.histograms(costa, "GR",
              title="Raw GR - wells disagree", histtype="step")
pp.histograms(normalized, xlabel="normalized GR (P5=0, P95=100)",
              title="Normalized GR - aligned", histtype="step");
../../_images/752e525ffc9d7456810456ac7017307ae01e198e5a7f218efc316d821c902d8a.png ../../_images/02a82b5a68e06e1b715513cb7a6ba872ea67f804e6cc21970a204c95a33050e7.png

The second (normalized) histogram shows the distributions brought into register: a normalized GR of, say, 20 marks the same relative “cleanness” in every well, so a field-wide cutoff behaves consistently. (Choosing P5/P95 as anchors assumes each well truly samples both clean and shaly rock - always sanity-check that assumption before normalizing.)

Pitfalls and parameter choices

  • Standardize first, everything else second. Bad-hole, value-range, and normalization all look curves up by name; if names are inconsistent they silently miss curves.

  • pp.interpret standardizes for you. Its normalization step runs this standardization by default (standardize_input left unset) on the copy of the well it interprets: vendor mnemonics get standard aliases (rename_input_curves=True renames them instead), units are converted, and implausible values are removed with a DataQualityWarning (from petrophys.exceptions). Pass standardize_input=False to interpret the curves as read.

  • standardize_curves mutates the well. Load a fresh copy if you need an untouched “before” for comparison.

  • Bad-hole needs a bit-size source. With no header bit size, detection falls back to the BS curve. With neither, detect_washout flags no washout: it applies the |DRHO| test only at samples that also have a CALI-BS value (bad_hole_flags(..., drho_alone=True) tests it alone, as the workflow’s bad_hole step does). COSTA wells have no caliper, which is why we demoed washout on GeoLink.

  • Value-range QC is curve-specific. It uses a physical rule per mnemonic, so a standardized name is what unlocks the right rule.

  • Normalization anchors are assumptions. P5/P95 are robust, but if a well never penetrates clean rock, forcing its P5 to 0 will over-clean it. Pick anchors that reflect a shared geological reference where possible.

Recap

  • Standardization (CurveStandardizer / standardize_curves, ALIAS_MAP) maps aliases like DT/RT to standard DTC/RDEP and normalizes units - do it first.

  • Unit labels can be wrong: standardize_core_saturation infers percent core saturation and takes a declared source_unit.

  • Value-range QC (apply_value_range_qc, value_range_qc_note) nulls or clips physically impossible or implausible readings using a per-curve rule table (some bounds are physics, others - like RDEP > 2000 ohm.m - are plausibility screens).

  • Bad-hole detection (detect_washout / WashoutDetection) flags unreliable intervals from CALI-BS (and DRHO) and attaches the flags as curves; pp.interpret(..., bad_hole={...}) or LAS header parameters set its thresholds.

  • Normalization (NormalizationModule) rescales a curve to a common range across wells so field-wide cutoffs are meaningful.

  • Always inspect before/after and be able to justify each edit physically.

Try it yourself

Exercise 1. Run CurveStandardizer().report(...) on a GeoLink well (e.g. 15_9-14). Which curves are recognized, and are any unit conversions proposed?

Exercise 2. Re-run detect_washout on 30_6-5 with a stricter caliper threshold (detect_washout(w, cali_threshold=0.75)). Does the flagged bad-hole percentage go up or down, and why?

Exercise 3. Normalize RHOB (instead of GR) across the five COSTA wells with NormalizationModule().normalize(well["RHOB"], ...) and overlay the before/after histograms. Does density need normalization as much as gamma ray does?

What’s next

That completes the data-conditioning trio (00-02), but Part A - Foundations keeps going: lessons 03 through 09 build the core interpretation science on this clean foundation - clay/shale volume from the gamma ray (03_clay_volume.ipynb is next), then porosity, lithology and mineral solving, formation water, water saturation, permeability, and reservoir quality / net pay. Part B (lessons 10-21) is the advanced track: the dynamic workflow, formation analysis, core and digital core, ML imputation, NMR, capillary pressure, borehole images, the visualization masterclass, the multiwell field study, LLM context generation, the MCP server for LLM agents and custom workflows. Everything downstream consumes exactly the conditioned Well you have learned to produce here.