simandoux

petrophys.interpretation.saturation.simandoux

simandoux(rt, rw, phi, vcl, rcl, a=1.0, m=2.0, n=2.0, *, modified=False)[source]

Calculate water saturation using the Simandoux equation.

1/Rt = (phi^m / (a * Rw)) * Sw^n + (Vcl / Rcl) * Sw

This is the Simandoux equation with Sw in the clay term (Bardon and Pied, 1969). modified=True gives the modified Simandoux equation, whose sand term is divided by (1 - Vcl):

1/Rt = (phi^m / (a * Rw * (1 - Vcl))) * Sw^n + (Vcl / Rcl) * Sw

For n=2 an exact quadratic solution is used. For n != 2 the equation is solved numerically via Brent’s method.

Parameters:
  • rt (float or np.ndarray) – True formation resistivity (ohm.m)

  • rw (float) – Formation water resistivity (ohm.m)

  • phi (float or np.ndarray) – Effective porosity (v/v)

  • vcl (float or np.ndarray) – Clay volume (v/v)

  • rcl (float) – Clay resistivity (ohm.m)

  • a (float, optional) – Tortuosity factor (default: 1.0)

  • m (float, optional) – Cementation exponent (default: 2.0)

  • n (float or np.ndarray, optional) – Saturation exponent (default: 2.0); one value, or one per sample

  • modified (bool, optional) – Divide the sand term by (1 - Vcl), the modified Simandoux equation (default: False). Vcl is capped at 0.99 there.

Returns:

Water saturation (0-1). NaN where Rt or an Rw array is at or below zero.

Return type:

float or np.ndarray

Raises:

ValueError – If a scalar rw or rcl is at or below zero.