invert_step_profile

petrophys.interpretation.electrical.invasion.invert_step_profile

invert_step_profile(
readings,
tools,
*,
rxo=None,
di_range=(8.5, 120.0),
n_diameters=200,
noise=0.02,
)[source]

Invert resistivity readings for Rt, Rxo and invasion diameter, sample by sample.

Parameters:
  • readings (mapping) – Apparent resistivity (ohm.m) per tool name, e.g. {"RSHA": ..., "RMED": ..., "RDEP": ...}; the names match tools.

  • tools (sequence of ToolResponse) – Response of each reading.

  • rxo (array-like, optional) – Measured flushed-zone resistivity (e.g. MSFL). It fixes Rxo, so two readings suffice.

  • di_range ((float, float)) – Invasion diameters to search, inches.

  • n_diameters (int) – Grid size (geometric spacing).

  • noise (float) – Relative reading error (0.02 = 2 %). Solutions whose RMS relative misfit is within it are equally valid; their span is reported as rt_low-rt_high and di_low-di_high. When noise is the standard error of the readings the range is roughly a one-standard-deviation interval.

Returns:

Rt, Rxo, di (inches), misfit, a flag where the answer is at the edge of di_range (the readings do not constrain it there) and the deepest reading’s flushed-zone share. Samples with a missing or non-positive reading are NaN. Where Rxo is close to Rt the diameter is not determined (any di fits).

Return type:

InvasionInversionResult