archie

petrophys.interpretation.saturation.archie

archie(rt, rw, phi, a=1.0, m=2.0, n=2.0)[source]

Calculate water saturation using Archie equation.

Sw^n = a × Rw / (φ^m × Rt)

Parameters:
  • rt (float or np.ndarray) – True formation resistivity (ohm.m)

  • rw (float) – Formation water resistivity (ohm.m)

  • phi (float or np.ndarray) – Porosity (v/v)

  • a (float, optional) – Tortuosity factor (default: 1.0)

  • m (float, optional) – Cementation exponent (default: 2.0)

  • n (float, optional) – Saturation exponent (default: 2.0)

Returns:

Water saturation (0-1): a float for scalar inputs, else an array. NaN where Rt or an Rw array is at or below zero.

Return type:

float or np.ndarray

Raises:

ValueError – If a scalar rw is at or below zero.

Examples

>>> sw = archie(rt=10, rw=0.05, phi=0.20)
>>> print(f"Sw = {sw:.2f}")
Sw = 0.35