Nuclear Magnetic Resonance (NMR) logging measures the relaxation of hydrogen protons in the pore fluid. NMR porosity does not require the matrix-density or matrix-slowness endpoints used by density and sonic porosity. Its interpretation still depends on fluid hydrogen index, polarization time, echo spacing and borehole conditions. T2 distributions can constrain pore sizes and bound/free-fluid volumes under suitable fluid, wettability and surface-relaxation assumptions; permeability comes from an empirical transform, not a direct measurement.

This lesson works the petrophys.interpretation.nmr toolkit on a real CMR log: the Schlumberger CMR summary deliverable from Daydream 1 (QGC, ATP 645, Bowen Basin, Queensland) - the same publicly released well whose FMI drives lesson 16. Two depth sections ship with the package; we use the deep one (3755-4145 m) and leave the shallow one for the exercises.

The deliverable is a summary export: total and free-fluid porosity, the T2 cutoff and the vendor permeabilities. It does not contain the per-depth T2 distribution (the T2 bins), so this lesson works with the summary curves and shows how the library refuses bin-based products rather than inventing them.

Learning goals

By the end of this lesson you will be able to:

  • Load a real CMR summary deliverable into NMRData with from_las (mnemonic aliases, automatic v/v-to-pu conversion, MBVI derived as MPHI - MFFI).

  • Read the porosity partition (bound vs free fluid) and Swirr from real curves, at the T2 cutoff recorded in the file itself.

  • Compute Timur-Coates permeability from the summary curves and validate it against the vendor’s own KTIM, recovering the vendor’s constant with calibrate_coates.

  • Know which products need T2 bins (T2 distribution, T2lm, SDR permeability, pore size) and how NMRData refuses rather than guesses when they are absent.

Why this matters (the physics)

After a polarizing pulse, hydrogen protons in the pore fluid relax back to equilibrium with a transverse relaxation time \(T_2\). In a water-wet rock the dominant mechanism is surface relaxation, and to first order

\[\frac{1}{T_2} \approx \rho_2\,\frac{S}{V},\]

where \(\rho_2\) is the surface relaxivity and \(S/V\) is the pore surface-to-volume ratio. Small pores have a large \(S/V\) and relax fast (short \(T_2\)); large pores relax slowly (long \(T_2\)). So the measured T2 distribution is a proxy for the pore-size distribution:

  • Short \(T_2\) -> tiny/clay-bound and capillary-bound water -> irreducible (BVI).

  • Long \(T_2\) -> large pores holding movable (free) fluid (FFI).

A processing T2 cutoff partitions these volumes under the chosen model. The total area under the T2 distribution is the NMR porosity (MPHI) after the acquisition and fluid-response corrections. A bound/free-fluid split is an interpretation: short-T2 hydrocarbons and wettability can invalidate a simple identification of BVI with water. The 33-ms and 92-ms defaults are starting parameters, not universal contacts between pore or fluid types. A summary export such as ours keeps the results of that split (total porosity, free fluid, the cutoff used) but not the distribution itself.

Prerequisites

This lesson assumes you have worked through the Part A porosity (04) and permeability (08) lessons. Basic familiarity with porosity units (fractions vs porosity units, “pu” = percent) is helpful.

import pandas as pd
import petrophys as pp
from petrophys.interpretation.nmr import NMRData

pd.set_option("display.precision", 3)
pd.set_option("display.max_columns", 30)

1. Load the real CMR deliverable

The bundled daydream1_cmr.las is the service company’s standard CMR summary export: total porosity TCMR, free fluid CMFF, 3-ms porosity CMRP_3MS, the vendor’s SDR and Timur permeabilities KSDR / KTIM, the T2CUTOFF used in the delivered processing, plus GR and calipers for QC.

NMRData.from_las does the housekeeping:

  • resolves CMR mnemonics onto the MRIL-style names the container uses (TCMR -> MPHI, CMFF -> MFFI),

  • converts fractional (v/v) porosities to pu,

  • derives MBVI = MPHI - MFFI when no bound-fluid curve is present,

  • reads the T2 cutoff from the T2CUTOFF curve, unless you pass t2_cutoff= (which then holds at every depth),

  • stores the vendor permeabilities and every remaining curve (stored_permeability, extra_curves).

One quirk of the file: it is written deepest-first (decreasing depth). That is a valid, monotonic depth index, so it loads without a warning, and per-sample NMR arithmetic is unaffected. Just remember that the first row is the deepest sample (the export table in section 5 shows it).

nmr = NMRData.from_las(pp.sample("daydream1_cmr"))
nmr
NMRData(samples=15606, depth=3755.0-4145.1, MFFI, MBVI, stored perm, schlumberger_cmr, cutoff=33.0ms)

15,606 samples from 3755.0 to 4145.1 m, free and bound fluid (MFFI, MBVI), the vendor permeabilities, and the 33 ms cutoff read from the T2CUTOFF curve. nmr.stored_permeability holds KSDR and KTIM, nmr.extra_curves the other curves of the file.

2. Summary curves vs T2 bins

This deliverable carries summary curves only - the per-depth T2 bin amplitudes (the full T2 distribution) were never exported to LAS (nmr.has_bins and nmr.has_t2lm are False). That rules out the bin-based products:

  • the T2 distribution itself and its log-mean T2lm,

  • SDR permeability (\(k = C\,\phi^4\,T2_{lm}^2\)), which needs T2lm,

  • pore-size estimates from surface relaxivity,

  • re-splitting BVI/FFI at a different cutoff (the vendor’s split at 33 ms is baked into CMFF).

When bin data exist, NMRData ingests them via from_csv / bin_mnemonics (MRIL P1...P8 or T2B01...T2B08). We do not fabricate bins to demo those methods - and the container is honest when asked for something the data cannot support: nmr.permeability_sdr(prefer_stored=False) raises ValueError: T2lm requires either T2 bin data (P1–P8) or a T2LM curve loaded from the LAS file (section 4b lists the bundled teaching examples that do carry bins). Called without prefer_stored=False, nmr.permeability_sdr() returns the vendor’s KSDR, computed in the service company’s processing from the full T2 distribution.

3. Porosity partition and Swirr

nmr.to_dataframe() puts the curves in one table, including the derived MBVI and the NMR irreducible saturation \(S_{wirr} = MBVI/MPHI\) (nmr.swirr_nmr()). Their medians over the section:

table = nmr.to_dataframe()
table[["MPHI", "MFFI", "MBVI", "SWIRR"]].median()
MPHI     6.63
MFFI     0.49
MBVI     6.01
SWIRR    0.92
dtype: float64

The deep section sits in tight Permian coal measures, and the real curves say so: the median total NMR porosity is 6.6 pu, and nearly all of it is bound fluid (median MBVI 6.0 pu against 0.5 pu of MFFI). The median Swirr is 0.92.

nmr_panel draws the processed NMR curves with their QC: GR and cable tension, the calipers against bit size, the porosity partition, the permeabilities and Swirr.

cmr = pp.read(pp.sample("daydream1_cmr"))
pp.nmr_panel(cmr);
../../_images/9c287c20ad5aba83452ea6931ce2ea7fa307ce07cb24e0a042c429d51bde49ad.png

The permeability track (log scale, 0.0001-100 mD) shows how tight the section is: 85 % of KTIM and 89 % of KSDR lie below 0.01 mD, and only thin streaks, the same depths as the porosity spikes, pass 1 mD; a few pass 10 mD (KTIM at most 52 mD, KSDR 82 mD).

QC: the high-TCMR spikes

TCMR spikes above 30 pu in thin streaks. The companion curves identify intervals requiring QC, but do not uniquely establish the cause of each spike:

  • Possible coal intervals. Some spikes have lower GR than the section average. Low GR alone does not identify coal or quantify its NMR response; confirm lithology and the fluid/acquisition response independently.

  • Hole enlargement. Some spike samples have caliper more than an inch over bit size. Borehole-fluid contamination is a possible contribution; the caliper flag is not a quantitative NMR correction.

Always read an NMR porosity spike against GR and caliper before calling it reservoir. The spike samples, their median GR against the rest, and how many of them sit in washout (HD1 more than 1 in over bit size):

(table.assign(spike=table["MPHI"] > 30, washout=table["HD1_PPC1"] > table["BS"] + 1)
      .groupby("spike").agg(samples=("MPHI", "size"), median_GR=("GR_EDTC", "median"), in_washout=("washout", "sum")))
samples median_GR in_washout
spike
False 15412 107.141 96
True 194 69.776 95

194 samples read above 30 pu (spike True). Their median GR is 70 API against 107 API for the rest of the section, and 95 of them, about half, sit in washout.

4. Timur-Coates permeability, validated against the vendor

The Timur-Coates model needs only the summary curves:

\[k_{TC} = \left(\frac{\phi}{C}\right)^{a} \left(\frac{FFI}{BVI}\right)^{b}\]

with textbook defaults \(C=10\), \(a=4\), \(b=2\) (\(\phi\) in pu, \(k\) in mD). The LAS also carries the vendor’s own Timur curve KTIM, reported by the vendor - a rare chance to validate the library against the service company on identical inputs.

One API gotcha first: permeability_coates() returns the stored vendor curve when one was loaded (prefer_stored=True is the default). To compute from the summary curves, pass prefer_stored=False.

kc = nmr.permeability_coates(prefer_stored=False)      # library, defaults
nmr.calibrate_coates(nmr.depth, nmr.stored_permeability["KTIM"])
NMRCalibration(model=coates, n=13171, c=9.62, a=4, b=2, R²_log=0.956, RMSE_log=0.178 dec)

calibrate_coates fits the constant \(C\) of the model to the vendor’s KTIM, on the 13,171 samples where KTIM is positive. To see the agreement sample by sample, we add the library curve to the well read for the panel (pp.read keeps the file’s deepest-first order, as NMRData does) and crossplot the two on log axes.

cmr.add_curve("K_TC_LIBRARY", kc, "mD")
cp = pp.crossplot(cmr, "KTIM", "K_TC_LIBRARY", x_log=True, y_log=True,
                  xlim=(1e-4, 1e2), ylim=(1e-4, 1e2), title="Daydream 1: library vs vendor Timur-Coates")
cp.add_line([1e-4, 1e2], [1e-4, 1e2], color="red", linewidth=1, label="1:1")
cp.show()
[repository]\src\petrophys\visualization\style.py:102: DataQualityWarning: Crossplot input: 2435 of 15606 value(s) cannot be represented on the selected axes (zero-based flat indices [0, 1, 2, 3, 4]). Nonfinite and nonpositive logarithmic-axis points are omitted.
  return _label_short_log_axes(function(*args, **kwargs))
../../_images/b85f274240a9ffa3c1466e0cda7181dbeb650682b00c3e29852b3e24b56ef21f.png

Reading the validation

The fit recovers a constant \(C\) = 9.62, close to the textbook default of 10, with a log-space \(R^2\) of 0.956 - the library and the vendor implement the same model with essentially the same constants. The remaining scatter (RMSE_log 0.178 decades) is largest below 0.001 mD, where the LAS’s four-decimal export quantises KTIM (step 0.0001 mD), with some contribution from rounding of the exported porosities.

Two honest caveats. First, this validates the implementation, not the permeability: both curves come from the same empirical model on the same inputs. Absolute accuracy still requires calibration to core (calibrate_coates with real plug permeabilities, exactly as used here but with core data). Second, KSDR cannot be reproduced the same way - it needs T2lm from the bins this export does not carry - which is precisely why bin data are worth requesting from the vendor.

4b. Other bundled NMR examples

The bin-based products and the core and density-neutron comparisons cannot be shown on Daydream 1. The library bundles three separate teaching datasets (Craig Phillips) for them. None of them belongs to Daydream 1, and none should be joined to it or to each other:

  • pp.sample("phillips_nmr_bins") - an eight-bin T2 example with explicit centres of 4-512 ms. NMRData.bvi_from_bins / ffi_from_bins split at the container’s t2_cutoff (33 ms by default, T2_CUTOFF_CLASTIC; T2_CUTOFF_CARBONATE is 92 ms) or at a cutoff_ms you pass, splitting the bin that straddles the cutoff by its log-T2 width. The file’s supplied summaries are a whole-bin split at 32 ms, which bvi_from_bins(cutoff_ms=32.0, partial_bins=False) and the matching ffi_from_bins call reproduce. Its source well and acquisition are not identified, so it demonstrates the arithmetic, not a field interpretation.

  • phillips_cmr_log / phillips_cmr_core - scalar NMR curves with core permeability over the same interval, enough for a Timur-Coates calibration to core (calibrate_coates with plug permeabilities). They carry no T2 bins or T2 log-mean, so they cannot calibrate SDR.

  • phillips_gulfcoast_nmr - conventional logs with scalar NMR from a Gulf Coast example (well unidentified), for comparing NMR porosity with density-neutron porosity. Mask -999.25 before converting the fractional MPHI/MBVI to pu, and review the porosity basis and hole quality first.

See the dataset notes for the T2 axis, mnemonics and loading examples.

5. Export all derived results

NMRData.to_dataframe() bundles the inputs, the derived curves (MBVI, SWIRR) and every vendor and extra curve into one table for QC or hand-off. Its K_COATES and K_SDR columns follow the same prefer_stored=True default as the methods: with vendor curves loaded they repeat KTIM and KSDR (which are also exported as KTIM_LAS / KSDR_LAS). To hand off the library’s own Timur-Coates, add it as a column, K_TC_LIBRARY here. Bin-dependent columns (T2lm, pore size) are simply absent because the bins are - the export never invents data. The first rows are the deepest samples:

table["K_TC_LIBRARY"] = kc
table.head()
DEPTH MPHI MFFI MBVI T2CUTOFF CMRP_3MS CMR_TEMP CDF STIT TENS HD1_PPC1 HD2_PPC1 BS GR_EDTC KSDR KTIM KSDR_LAS KTIM_LAS K_SDR K_COATES SWIRR K_TC_LIBRARY
0 4145.125 0.59 0.0 0.59 33.0 0.16 118.703 -171.989 0.004 3490.197 2.924 4.17 8.5 79.268 0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.0
1 4145.100 0.59 0.0 0.59 33.0 0.16 118.703 -168.357 0.037 3530.551 2.924 4.17 8.5 79.268 0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.0
2 4145.075 0.59 0.0 0.59 33.0 0.16 118.703 -164.725 0.071 3570.905 2.924 4.17 8.5 79.268 0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.0
3 4145.050 0.59 0.0 0.59 33.0 0.16 118.703 -161.094 0.105 3611.260 2.924 4.17 8.5 79.268 0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.0
4 4145.025 0.59 0.0 0.59 33.0 0.16 118.703 -157.462 0.139 3651.614 2.924 4.17 8.5 79.268 0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.0

Pitfalls & parameter choices

  • prefer_stored=True is the default. With vendor curves loaded, permeability_coates() / permeability_sdr() return the stored KTIM / KSDR. Pass prefer_stored=False when you mean “compute it yourself” - otherwise a comparison against the vendor compares the curve to itself.

  • Porosity units. The container works in pu; from_las converts fractional (v/v) CMR curves automatically. Only worry about units when calling the standalone sdr_permeability / coates_permeability functions.

  • SDR needs T2lm. No bins and no T2LM curve means no SDR - the method raises instead of guessing. Request bin exports (T2B01...) if you need it.

  • The cutoff is data, not folklore. Here 33 ms comes from the file’s T2CUTOFF curve (the clastic default; 92 ms is a configurable carbonate starting value, requiring calibration). With only summary curves you also cannot re-split at another cutoff - CMFF was computed in the vendor’s processing at 33 ms.

  • Validating against KTIM is not core calibration. It checks the implementation and constants; absolute permeability still needs plugs.

  • QC spikes before believing them. Low GR and caliper-over-bit flags warrant further lithology and borehole QC; they do not establish a unique cause.

  • This LAS is written deepest-first. The depth index is monotonic, so it loads without a warning and per-sample math is safe; the first row is the deepest sample, so sort by depth before any step that assumes shallow-to-deep order.

Reference: SLB describes T2 surface, bulk and diffusion relaxation, polarization-time dependence, and adjustable cutoff processing.

Recap

  • A real CMR summary deliverable (Daydream 1) loads in one call: NMRData.from_las(path) - aliases, pu conversion, MBVI = MPHI - MFFI, cutoff, and vendor curves all handled.

  • The porosity partition says tight coal measures: low total NMR porosity, very little free fluid and a high median Swirr; TCMR spikes need independent lithology and borehole QC before they can inform a pay interpretation.

  • Library Timur-Coates matches the vendor’s KTIM closely, and calibrate_coates recovers a constant \(C\) close to the textbook 10.

  • T2-bin products (T2 distribution, T2lm, SDR, pore size) need bin data, which this summary export does not carry; the API refuses cleanly when they are absent, and the vendor’s delivered KSDR shows what those bins would buy.

Try it yourself

Exercise 1. Load the shallow section (pp.sample("daydream1_cmr_shallow"), about 2840-3050 m) the same way and compare its Swirr and KTIM distributions against the deep section. Which section has more free fluid?

Exercise 2. Re-run calibrate_coates with fit_exponents=True. Do the exponents move away from \((a, b) = (4, 2)\), and what does that say about the parameterisation the vendor used?

Exercise 3. TCMR - CMRP_3MS isolates the porosity relaxing faster than 3 ms (micro/clay-bound signal). nmr.mphi holds TCMR converted to pu; CMRP_3MS is in nmr.extra_curves. Check its values against its V/V label before subtracting - do they look like fractions or porosity units? Then plot the difference against GR_EDTC: does micro-porosity track shaliness?

What’s next

Continue with 15 - Capillary Pressure & Saturation-Height, where the bound/free-fluid ideas from NMR reappear as capillary equilibrium above the free-water level, and we predict water saturation from porosity, permeability and height.