CS5 - Saturation-Model Selection & Sensitivity (well 30/6-5)¶
Petrophys Case Studies - a decision-focused project lesson
Part 1 - The brief¶
“Which water-saturation model should we trust in this shaly sand, and how much does the choice move net pay and hydrocarbon pore volume (HCPV)? Quantify the sensitivity of the answer to both the model and the parameter assumptions.”
A subsurface team has a shaly-sand reservoir on the North Sea well 30/6-5. The gross rock volume is fixed by seismic; the volumetric uncertainty that the team controls comes almost entirely from the petrophysical water saturation (Sw). In a clean sand Archie’s equation is sufficient, but this interval carries clay, and clay adds an extra conductive path that Archie does not account for - so Archie reads Sw too high and undercounts pay. Several shaly-sand corrections exist (Simandoux, Indonesia, and the regional North Sea and Nigeria forms - plus the lab-data Waxman-Smits / Dual-Water family when CEC and SCAL exist) and they disagree.
The deliverable of this lesson is not a single number. It is:
A decision table - the five Sw models side by side, each with net pay, Sw averaged over the pay, and a hydrocarbon-pore-thickness index (
HCPV, metres of hydrocarbon-filled pore column).A sensitivity / tornado analysis - how much net pay and HCPV move when we sweep the key uncertain inputs (Rw, m, n, Vcl cutoff).
A reasoned recommendation - which model to trust here and why, with an uncertainty band on HCPV implied by the sensitivity.
This case study reuses the fundamentals taught in tutorial 07 (saturation) but is oriented toward a decision under uncertainty, not toward teaching the equations.
What you will learn
How to run several saturation models on one interval with a common parameter set (
pp.interpretwithsw_model=).How to turn model differences into a decision table of net pay and HCPV.
How to build a one-at-a-time sensitivity (tornado) and read which assumption to measure first.
How to quote an uncertainty band instead of a single number.
Prerequisites. Lesson 07 (water saturation models), lesson 09 (net pay; it also reconciles this well’s Rw) and case study CS1 (the full evaluation of the same well). The base install is enough.
Part 2 - The well & the data¶
Well 30/6-5 is a North Sea clastic well of the GeoLink dataset (depths in metres). It penetrates two sand packages relevant to us:
Interval |
Depth (m) |
Fluid |
Role in this study |
|---|---|---|---|
Brent Group sands ( |
2841 - 2958 |
hydrocarbon-bearing |
the reservoir we evaluate |
Statfjord sands |
3223 - 3556 |
water leg |
Pickett check of the Archie parameters (Sw~1; the regression still fails, and 4.2 shows why) |
The two-interval design is deliberate: a Pickett plot can only pin down the Archie parameters (m, and via the intercept Rw) from a water-bearing zone where Sw is known to be ~1. The deeper Statfjord water leg is that zone. The water-leg premise is solid here - CS1’s formation roll-up finds only scattered, low net-to-gross pay flags in the Statfjord and does not treat it as a target, and the NPD records no discovery there - but section 4.2 shows that a Pickett regression fails on this leg anyway, for reasons worth understanding.
What we have: GR, RHOB, NPHI, deep resistivity (RDEP), plus core (PHIC, SWC). What we are missing: no Rw measurement of our own (the header Rw comes from Statoil’s 1981 evaluation; 4.1 discusses it), no CEC/Qv lab data, no independent m/n from SCAL. Every one of those becomes an assumption that we flag and then stress-test in the sensitivity analysis - which is exactly the point of the brief.
A scope call on the core, stated explicitly rather than quietly dropped: the well carries core water saturations (SWC) inside the evaluated reservoir (counted below, in v/v). They exist, they sit in the interval, and a production study would benchmark the five Sw models against them - with the standard caveat that core saturations from non-preserved core are altered by mud-filtrate flushing and fluid loss during recovery. This study stays log-only by scope, so the core saturations are acknowledged, not used.
import warnings
import pandas as pd
import petrophys as pp
from petrophys.interpretation.core_analysis import core_data
# SWC and SOC are stored in percent though labelled 'frac' (CS1 explains); hide only that message.
warnings.filterwarnings("ignore", message="(SWC|SOC): inferred percent core saturation")
pd.set_option("display.precision", 3)
well = pp.read(pp.sample("30_6-5"))
core_data(well, top=2841, bottom=2958).to_dataframe()["CSW"].describe()
count 74.000
mean 0.482
std 0.159
min 0.137
25% 0.365
50% 0.474
75% 0.601
max 0.846
Name: CSW, dtype: float64
There are 74 core Sw points in the Brent Group, from 0.14 to 0.85 v/v.
Part 3 - Workflow plan¶
The study is a set of pp.interpret runs that differ in one thing at a time:
Base parameters - the operator’s documented Rw, a, m and n, and the clastic cutoffs.
Five runs, one per Sw model (
sw_model=). Clay volume, porosity, Rw and the cutoffs are computed the same way in every run; only the saturation equation changes.Pickett check on the water leg - an illustrative m and Rw from the Statfjord. The log-only Pickett is poorly constrained here, which is why the base case rests on the operator’s documented constants - a realistic petrophysical decision.
Decision table - net pay, average Sw and HCPV per model over the Brent Group, from
zone_summary().Parameter sensitivity - sweep Rw, m, n and the Vcl cutoff one at a time; build a tornado.
Recommendation - pick a model, quote an HCPV uncertainty band.
CS1 interprets the same well with the workflow’s auto-routed saturation model; here every run names its model. CS1 also leaves a, m and n to the workflow’s lithology defaults and assumes a 50 degF surface temperature, so its Brent Group net pay (24.4 m) is not the 26.1 m of the Archie run here; with this study’s constants and the default surface temperature the auto-routed run gives 26.1 m too.
Part 4 - Execution¶
4.1 Base parameters (documented, not guessed)¶
The LAS header carries the operator’s parameter block: Rw = 0.070 ohm.m at RWT = 230 degF
(reservoir temperature, Statoil’s 1981 evaluation). Lesson 09 cross-checks it against the completion-report
evaluation, which used the same Rw with a = 0.80, m = n = 2 - constants that reproduce their
zone-by-zone pay table and bracket the NPD’s 2907 m OWC (case study 1). We adopt that set as the
base case, with the clastic cutoffs (Vcl < 0.40, PHIE > 0.08, Sw < 0.60) for every sample.
The Rw is given with its temperature, so each run corrects it along the temperature profile.
The zone named in zones= changes no setting; it names the Brent Group interval so that
result.zone_summary() reports it. Documented is not the same as certain - the vintage of the
evaluation, the fact that the Rw is not our own measurement and the absence of SCAL all leave real
uncertainty, which is exactly what the tornado in Part 6 sweeps.
Model families and what each one is for:
Model |
Clay term |
When you reach for it |
|---|---|---|
Archie |
none |
clean sand baseline (biased high in shaly rock) |
Simandoux |
|
classic shaly-sand, dispersed clay |
Indonesia (Poupon-Leveaux) |
|
laminated/dispersed, high-Vcl robust |
North Sea (regional) |
|
North Sea shaly sands - the local convention for this well |
Nigeria-type (regional) |
|
Niger-delta-style laminated sands |
All five run on effective porosity with the clay handled by an explicit Vcl term, and take the
clay resistivity the workflow measures in the well’s shales (Rcl, the median deep resistivity of
the shale samples; the saturation step records it). The total-porosity, lab-data family
(Waxman-Smits, Dual-Water) needs CEC / Rwb measurements this well does not have, so it is
excluded rather than guessed - lesson 07 (section 4) explains why, and the workflow behaves
the same way: it runs Waxman-Smits only when cec and b_coeff are supplied, and Dual Water only
with a supplied rwb; it never estimates them.
BRENT = [{"zone": "Brent Group", "top": 2841, "bottom": 2958}]
BASE = dict(rw=0.07, rw_meas_temp="230 degF", a=0.8, m=2.0, n=2.0, # operator's evaluation
vcl_cutoff=0.40, phie_cutoff=0.08, sw_cutoff=0.60, # clastic standards
zones=BRENT)
MODELS = ["archie", "simandoux", "indonesia", "north_sea", "nigeria_schlumberger"]
runs = {model: pp.interpret(well, sw_model=model, **BASE) for model in MODELS}
4.2 Pickett check on the water leg¶
The Pickett plot is log(Rt) against log(PHI) for water-bearing points: the slope gives -m
and the intercept log(a*Rw). The plot below draws the cleaner Statfjord samples (Vcl up to
0.30) with the base-case lines (a = 0.8, m = n = 2 and the base Rw at Statfjord temperature, the
median of the run’s RW curve over the plotted points); pickett_analysis then fits the same
points by regression.
It fits m and the intercept with a = 1; n comes from SCAL, which we do not have.
from petrophys.interpretation.electrical.cementation import pickett_analysis
pp.crossplot(runs["archie"], "PHIE", "RDEP", top=3223, bottom=3556, a=0.8, vcl_max=0.30).show()
water = runs["archie"].well.depth_slice(3223, 3556) # the Statfjord water leg
pickett_analysis(water["RDEP"].data, water["PHIE"].data, vcl=water["VCL"].data, vcl_cutoff=0.30)[1]
[repository]\src\petrophys\visualization\style.py:102: DataQualityWarning: Pickett input: 41 of 22176 value(s) require porosity in (0,1] and finite positive resistivity (zero-based flat indices [20786, 20974, 20975, 20976, 20979]). Invalid points are omitted from this plot.
return _label_short_log_axes(function(*args, **kwargs))
[temporary directory]\ipykernel_4480\2980182672.py:5: UserWarning: Pickett fit gives m = 0.81, outside the usual 1.3-3 range: the samples are probably not all clean and water-bearing (Sw = 1). Fit the water leg only, or read m from the lower envelope of the points.
pickett_analysis(water["RDEP"].data, water["PHIE"].data, vcl=water["VCL"].data, vcl_cutoff=0.30)[1]
{'m': 0.8080444381750765,
'slope': -0.8080444381750765,
'intercept': -0.16660876274968506,
'rw': 0.6813829108969476,
'method': 'rma',
'r_squared': 0.4801969639203325,
'p_value': 7.856968250123597e-141,
'std_err': 0.018628814744084347,
'n_points': 978}
The clean, porous samples (dark) fall mostly between the Sw = 80% and 100% lines, a fifth of them just below the water line: the base-case constants read the water leg as wet, as they should. The regression tells a different story.
The fit is not usable. An m of 0.81 is far below the physical 1.6-2.1 range, the R-squared is only 0.48, and the apparent Rw (a = 1) is 0.68 ohm.m - against a base Rw near 0.065 ohm.m at this depth. That combination is not just noise - it is the signature of regressing through a mixed cloud. Deep resistivity changes little across the leg’s porosity range, so the low-porosity (tight or shaly) samples read far less resistive than Archie with m = 2 predicts and the most porous ones more resistive; scatter in porosity flattens a regression slope further, and a flatter slope lifts the intercept. Lesson 07 dissects exactly this trap on the same interval and shows the industry alternative: fix m at a plausible value and pick Rw from the lower envelope of the clean cloud - which lands close to the operator’s value. The regression is discarded, and the base case stays on the operator’s documented constants.
4.3 The decision table: five models over the Brent Group¶
zone_summary() rolls each run up over the Brent Group: net pay, pay / gross, and PHIE, Sw and
VCL averaged over the net-pay samples, plus HCPV, the hydrocarbon-pore-thickness index of the brief
(metres of hydrocarbon-filled pore column). Multiplied by area it becomes HCPV proper; because the area is
common to all models, the index carries the full model sensitivity of the volumetric answer.
decision = pd.concat({model: run.zone_summary() for model, run in runs.items()}).droplevel(1)
decision[["Net Pay (m)", "Pay/Gross", "Avg PHIE", "Avg Sw", "Avg VCL", "HCPV"]]
| Net Pay (m) | Pay/Gross | Avg PHIE | Avg Sw | Avg VCL | HCPV | |
|---|---|---|---|---|---|---|
| archie | 26.060 | 0.223 | 0.211 | 0.289 | 0.060 | 3.908 |
| simandoux | 30.175 | 0.258 | 0.202 | 0.302 | 0.083 | 4.251 |
| indonesia | 30.785 | 0.263 | 0.201 | 0.301 | 0.085 | 4.322 |
| north_sea | 28.346 | 0.242 | 0.205 | 0.291 | 0.077 | 4.128 |
| nigeria_schlumberger | 29.108 | 0.249 | 0.204 | 0.297 | 0.080 | 4.180 |
Archie books the least pay (26.1 m, HCPV 3.91 m); the four shaly-sand models book 28.3-30.8 m with HCPV 4.13-4.32 m, Indonesia the most. That ordering is the expected effect of unmodelled clay conductivity: Archie attributes the clay’s conduction to water, reads Sw too high in shaly sand and undercounts pay. The pay averages move little (average Sw 0.29-0.30 over the pay), because a shaly-sand model mostly adds marginal samples that sit just under the Sw cutoff.
Part 5 - Integrated result¶
5.1 Figure - the five Sw curves over the Brent Group¶
pp.plot with curves= draws several wells or results in one figure, a track per curve. Given a
mapping of runs, it labels each line with its key - here the model.
pp.plot(runs, curves=["VCL", "SW"], top=2841, bottom=2958, figsize=(8, 10)).show()
Reading the saturation track¶
The VCL curves of the five runs coincide (only the Sw equation differs). The Sw scale runs from 1 on the left to 0 on the right. In the clean Etive sand (about 2876-2890 m) all five models agree. Wherever VCL is raised in rock that keeps some porosity they part: Archie reads the wettest and the separation grows with Vcl. That is the clay-conductivity effect again. The shaly beds below 2900 m have no effective porosity, so every model reads Sw = 1 there.
One warning sign sits in the Ness Fm. shales (about 2855-2865 m, VCL 0.6-0.9): there the Nigeria-type form returns Sw as low as 0.05 - a shale reading as hydrocarbon - and the North Sea form has gaps where it finds no solution. Both over-correct for clay conductivity with the shale resistivity of this well. The Vcl cutoff keeps those samples out of the pay, so the decision table is not affected, but neither regional form should be trusted in the shales.
5.2 Figure - net pay and HCPV by model (the decision bar chart)¶
pp.bar_chart(MODELS, decision["Net Pay (m)"], value_labels=True, ylabel="Net pay [m]",
title="Brent Group: net pay by Sw model").show()
pp.bar_chart(MODELS, decision["HCPV"], value_labels=True, ylabel="HCPV [m]",
title="Brent Group: hydrocarbon pore thickness (HCPV index) by Sw model").show()
The model choice alone moves net pay by 4.7 m and HCPV by 0.41 m (about 10% of the Indonesia HCPV) - almost all of it the step from Archie to any shaly-sand model.
Part 6 - Parameter sensitivity (the tornado)¶
The decision table captured model uncertainty. Now we quantify parameter uncertainty for a single reference model. We use Indonesia as the reference - the robust workhorse for dispersed shaly sands, and the model recommended in Part 7 - and sweep each key input across a defensible low/high range while holding the others at base:
Assumption |
Low |
Base |
High |
Why uncertain |
|---|---|---|---|---|
Rw (ohm.m at 230 degF) |
0.05 |
0.070 |
0.09 |
Statoil’s value, not our own measurement; 1981 vintage |
m |
1.8 |
2.0 |
2.2 |
operator value, but no SCAL of our own |
n |
1.8 |
2.0 |
2.2 |
no SCAL |
Vcl cutoff |
0.30 |
0.40 |
0.50 |
pay-flag choice (standard = 0.40) |
parameter_sensitivity (in petrophys.evaluation) does the bookkeeping: it calls an evaluation
once at base and twice per assumption, and returns one row per assumption and output with low,
base, high and swing (|high - low|), widest swing first. The evaluation is one
pp.interpret run summarized over the Brent Group.
from petrophys.evaluation import parameter_sensitivity
def brent(sw_model="indonesia", **changes):
"""The Brent Group summary of one run: base settings with some of them changed."""
return pp.interpret(well, **{**BASE, "sw_model": sw_model, **changes}).zone_summary().iloc[0]
sens = parameter_sensitivity(brent, {
"Rw 0.05 / 0.09": ({"rw": 0.05}, {"rw": 0.09}),
"m 1.8 / 2.2": ({"m": 1.8}, {"m": 2.2}),
"n 1.8 / 2.2": ({"n": 1.8}, {"n": 2.2}),
"Vcl cutoff 0.30 / 0.50": ({"vcl_cutoff": 0.30}, {"vcl_cutoff": 0.50}),
}, outputs=["Net Pay (m)", "HCPV"])
sens[["output", "case", "low", "base", "high", "swing"]]
| output | case | low | base | high | swing | |
|---|---|---|---|---|---|---|
| 0 | Net Pay (m) | m 1.8 / 2.2 | 33.376 | 30.785 | 25.755 | 7.620 |
| 1 | Net Pay (m) | Rw 0.05 / 0.09 | 32.461 | 30.785 | 27.584 | 4.877 |
| 2 | Net Pay (m) | Vcl cutoff 0.30 / 0.50 | 29.718 | 30.785 | 31.242 | 1.524 |
| 3 | Net Pay (m) | n 1.8 / 2.2 | 31.242 | 30.785 | 30.328 | 0.914 |
| 4 | HCPV | m 1.8 / 2.2 | 4.723 | 4.322 | 3.723 | 1.000 |
| 5 | HCPV | Rw 0.05 / 0.09 | 4.683 | 4.322 | 3.894 | 0.789 |
| 6 | HCPV | n 1.8 / 2.2 | 4.559 | 4.322 | 4.098 | 0.461 |
| 7 | HCPV | Vcl cutoff 0.30 / 0.50 | 4.240 | 4.322 | 4.352 | 0.111 |
hcpv = sens[sens["output"] == "HCPV"]
pp.tornado_plot(hcpv["case"], hcpv["low"], hcpv["high"], base=hcpv["base"].iloc[0],
xlabel="HCPV (m)", title="Indonesia: Brent Group HCPV sensitivity");
Highest-value measurement¶
The widest bar is where a measurement buys the most certainty. Here it is m, followed by Rw (HCPV swings of 1.00 m and 0.79 m), then n (0.46 m) and the Vcl cutoff (0.11 m). The fix differs by lever: SCAL formation-factor tests on core plugs pin down m, resistivity-index tests pin down n, a produced- or formation-water sample pins down Rw, and core or test data calibrate the clay cutoff. Note how close the leading bars are - a small change in the sweep ranges could reorder them, so budget for the top two rather than only the first. On net pay the order is the same at the top, but the Vcl cutoff moves ahead of n.
6.1 Combining model + parameter uncertainty into an HCPV band¶
To quote an honest range we combine both sources:
Low case: the most pessimistic model (Archie) at its most pessimistic parameter corner.
High case: the recommended model (Indonesia) at its most optimistic parameter corner - the upper edge of the band is parameter-driven, not model-driven.
Base case: the recommended model at base parameters.
band = {"low: Archie, pessimistic corner": brent("archie", rw=0.09, m=2.2, n=2.2, vcl_cutoff=0.30),
"base: Indonesia": runs["indonesia"].zone_summary().iloc[0],
"high: Indonesia, optimistic corner": brent(rw=0.05, m=1.8, n=1.8, vcl_cutoff=0.50)}
pd.DataFrame(band).T[["Net Pay (m)", "Avg Sw", "HCPV"]].astype(float)
| Net Pay (m) | Avg Sw | HCPV | |
|---|---|---|---|
| low: Archie, pessimistic corner | 19.964 | 0.337 | 2.920 |
| base: Indonesia | 30.785 | 0.301 | 4.322 |
| high: Indonesia, optimistic corner | 39.015 | 0.239 | 5.555 |
Part 7 - Recommendation & deliverable¶
Recommended model: Indonesia (Poupon-Leveaux).
Reasoning:
The rock is shaly. The Ness Fm. and the lower Etive carry shaly beds, and Archie ignores clay conductivity: it reads the wettest of the five models and systematically undercounts pay here (the Sw overlay, where the gap grows with Vcl). Archie is the wrong tool for this interval and is kept only as a pessimistic bookend.
Indonesia is the right shaly-sand workhorse. Its
Vcl^(1-Vcl/2)clay term is numerically stable across the full Vcl range (including the shales; the pay window itself is Vcl < 0.40) and does not require lab data we do not have. Simandoux tracks it closely but is less robust at high Vcl.The lab-data family was excluded, not guessed. Waxman-Smits and Dual-Water need clay-specific laboratory inputs (CEC/Qv, Rwb) that this well does not have; running them on guesses produces answers that are only as good as the guesses (lesson 07, section 4). The two regional field-data forms take their place in the comparison, and the North Sea form (the local convention) landing close to the other shaly-sand models in net pay and HCPV is useful corroboration.
The shaly-sand models agree closely. Their HCPV spans 4.13-4.32 m, a spread small next to the Archie-to-shaly-sand step, so the choice among shaly-sand models matters much less than the choice to use one at all. Indonesia sits at the top of that narrow range.
Deliverable - the numbers with their uncertainty:
Net pay (m) |
HCPV (m) |
|
|---|---|---|
Recommended base case (Indonesia, base parameters) |
30.8 |
4.32 |
Band (Archie pessimistic corner - Indonesia optimistic corner) |
20.0 - 39.0 |
2.92 - 5.56 (-32% / +29% vs base) |
Dominant levers (tornado order) |
m, Rw |
The honest headline for the team: the shaly-sand correction moves HCPV materially versus Archie, and the residual volumetric uncertainty is set mainly by the widest tornado bars. Book the Indonesia base case, carry the band, and acquire the measurement for the widest bar - SCAL formation-factor tests for m - before committing volumes.
Part 8a - Limitations & assumptions¶
Everything below was assumed, not measured, and each is a candidate for the next data-acquisition dollar:
Rw = 0.070 ohm.m at 230 degF (reservoir temperature) - documented (header value from Statoil’s 1981 evaluation, cross-checked against its pay table in lesson 09) but not measured by us, and the evaluation is 1981 vintage. The tornado in Part 6 ranks how much it matters relative to m, n and the Vcl cutoff.
a = 0.80, m = 2.0, n = 2.0 - the operator’s evaluation constants, adopted without SCAL of our own. The log-only Pickett regression on the water leg is unusable (unphysical slope, weak R-squared).
No CEC / Rwb lab data - the Waxman-Smits and Dual-Water family was therefore excluded from the comparison rather than run on guesses (the workflow applies the same rule). The regional North Sea and Nigeria forms stand in as field-data alternatives.
Clay volume and porosity are the workflow’s: VCL is the lower of the gamma-ray and neutron-density estimates, with the gamma-ray endpoints picked over the whole well, and the saturation step uses the core-corrected porosity PHIE_CC (one correction fitted on the Brent Group plugs and applied at every depth). A clay volume calibrated on the Brent Group alone would move every shaly-sand model.
Core SWC was not used - the points counted in Part 2 sit inside the evaluated reservoir; a production study would benchmark the five models against them (with the flushing caveat on core saturations). Here the study stayed log-only for scope, so the model choice rests on physics and spread, not on a core match.
Fixed cutoff set (Vcl 0.40 / PHIE 0.08 / Sw 0.60 - the clastic standards) - conventional rather than derived; the Vcl cutoff was included in the sensitivity so its effect is visible in the tornado.
HCPV is a per-well column index, not a mapped volume - area/NTG closure comes from the static model, which is outside this lesson’s scope.
Part 8b - Appendix: reproduce on another well¶
To repeat this study on a different well, change the sample, the reservoir zone and the base parameters; the runs, the table and the tornado stay the same.
w2 = pp.read(pp.sample("<well_id>"))
BASE = dict(rw=..., rw_meas_temp=..., zones=[{"zone": "Reservoir", "top": ..., "bottom": ...}])
runs = {model: pp.interpret(w2, sw_model=model, **BASE) for model in MODELS}
pd.concat({model: run.zone_summary() for model, run in runs.items()})
Guidance for a new well:
Pick the water leg for Pickett from a zone you independently believe is Sw~1 - and verify that belief against sibling studies and any core data before trusting it; if the fit is weak (low R-squared, m outside 1.6-2.1), treat it as illustrative and fall back to documented or basin-typical m/n as we did here.
State the temperature of every Rw you use (
rw_meas_temp), so it is corrected to formation temperature along the well.Keep the five-model run and the tornado - the decision value is in the spread and in identifying the most sensitive assumption, not in any single deterministic Sw.
Recap¶
Five field-data saturation models ran on the Brent Group sands as five
pp.interpretruns with one parameter set; Archie reads the wettest, and the four shaly-sand models agree closely with one another in net pay and HCPV.A log-only Pickett regression on the Statfjord water leg is unusable here; the base case uses the operator’s documented constants (Rw 0.070 ohm.m at 230 degF, a = 0.80, m = n = 2).
The tornado ranks the parameter levers, and the widest bars name the measurement to acquire first.
The deliverable is a recommended model (Indonesia), a base case and a combined model + parameter band on HCPV - not a single number.
Exercises¶
Widen the Rw sweep to 0.04-0.10 ohm.m. Does the tornado order change? What does that tell you about how the sweep ranges drive the “most sensitive” answer?
Look at the core.
pp.plot(runs["indonesia"], top=2841, bottom=2958, template="petrophysics")draws the core SWC points on the saturation track. Plot the Archie run the same way: which model do the core points favour, and where do they disagree with both?The porosity the saturation step uses. Repeat the Pickett regression with
water["PHIE_CC"]in place ofwater["PHIE"]. Does the fit improve?
What’s next¶
Compare with CS1, which interprets the same well in one pp.interpret call and uses the
workflow’s auto-routed saturation model; the tornado here tells you which of CS1’s settings to
challenge first.