MDTPickingConfig

petrophys.interpretation.saturation.height.MDTPickingConfig

class MDTPickingConfig(
edge_seconds=15.0,
tail_seconds=30.0,
guard_seconds=3.0,
min_drawdown_bar=0.5,
min_recovery_bar=0.2,
plateau_tolerance_bar=0.05,
repeat_tolerance_bar=0.1,
mud_agreement_bar=2.0,
max_depth_drift_m=0.25,
max_gap_seconds=None,
)[source]

Analysis thresholds in the units in each name, not gauge specifications.

Plateau tolerance limits both 5th-to-95th percentile pressure spread and fitted pressure change over the final tail. The preceding tail must agree. Review defaults for acquisition resolution and measurement precision. max_gap_seconds left as None flags a time gap over 5 s or five sampling intervals, whichever is longer; a value set is used as given.

Attributes

Parameters:
  • edge_seconds (float)

  • tail_seconds (float)

  • guard_seconds (float)

  • min_drawdown_bar (float)

  • min_recovery_bar (float)

  • plateau_tolerance_bar (float)

  • repeat_tolerance_bar (float)

  • mud_agreement_bar (float)

  • max_depth_drift_m (float)

  • max_gap_seconds (float | None)

edge_seconds: float = 15.0
tail_seconds: float = 30.0
guard_seconds: float = 3.0
min_drawdown_bar: float = 0.5
min_recovery_bar: float = 0.2
plateau_tolerance_bar: float = 0.05
repeat_tolerance_bar: float = 0.1
mud_agreement_bar: float = 2.0
max_depth_drift_m: float = 0.25
max_gap_seconds: float | None = None